Friday , 13 December 2024
Home » BDCOM SWITCH » BDCOM Switch Loop Protection

BDCOM Switch Loop Protection

BDCOM Switch Loop Protection

BDCOM Switch Loop Protection, To protect the loop, please use the following command on the bdcom switch.

1.. Please use the following command on the up-link interface of the core switch with delivery –

Configure # loopback-detection
Change #int gigaethernet 0/8
Config_config8 # enable loopback-detection
Config_config8 # Turn off loopback-detection control
Switch _config8 # exit
Change Config # No Error-Disabled-Restore

2. Shut down vlan1 (if not vlan1 service)

Configure _config # interface vlan 1

Config _v1 # close
Configure _config # exit
Configure _config #vlanDisable-Learning1

3. Use storm control to broadcast in the port

Change #config
Configure _config # interface gigaethernet 0/1

Change _config_g0 / 1 # storm-control?

Broadcast – broadcast address storm control

Multi-cast – multicast address storm control

Unicast – Unknown-unicast address storm control

Change _config_g0 / 1 # storm-control broadcast limit?

<1-1048575> – Enter the integer portion of the storm suppression level (pps)

B: Use the value 200 to check

Check Also

VLAN BASED BANDWIDTH CONTROL IN BDCOM SWITCH

VLAN BASED BANDWIDTH CONTROL IN BDCOM SWITCH

VLAN BASED BANDWIDTH CONTROL IN BDCOM SWITCH VLAN BASED BANDWIDTH CONTROL IN BDCOM SWITCH, BDCOM …

Leave a Reply

Your email address will not be published. Required fields are marked *

Translate »